A repowering study required verified heat balance figures at site ambient conditions rather than ISO reference conditions. AOGC produced the performance model, compared simple and combined cycle configurations and quantified the output and efficiency penalty from site altitude and summer ambient temperature.
Power generation
Performance modelling for a repowering study
Heat balance and output verification for a repowering study, comparing simple and combined cycle configurations at site conditions.
Siemens SGT-800
Platform
Plant performance modelling
Scope
2024
Year
Central Asia
Region

Send us the nameplate data — we will identify the part
Part numbers, quantities and delivery terms in one form. An engineer reviews every enquiry and replies with a written quotation and lead times.